Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Model: RPR (67P).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular OMRON S8VM-01524C.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system
S8VM-01524C
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries OMRON S8VM-01524C.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring OMRON S8VM-01524C. Type: Cable with Connector on One End,
(one ferrite core provided, 30-dia × 39 mm).
Cable length: 2 m.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings. Sensor type: 3 wire DC / DC (NPN) 3 - 4 2 wire.
Input points: 6.
The I/O sensor connector for centralized wiring,
And the province of the number of processes, strong environmental resistance as the goal,
The outer control relay box.
Compact and strong centralized wiring trrunk box conforming to IP67 S8VM-01524C.
The corresponding sensing I/O connector mode proximity switch, limit switch,
Photoelectric switch.
With the power to show LED, action shows LED.
The installation dimensions are the same and are not related too the number of input points,
Therefore, the addition of a simple exchange S8VM-01524C.
A series of sensors with self diagnostic features are added to the product.