SRT2-ROC08 | OMRON Relay-mounted Remote I/O Terminals SRT2-ROC08
OMRON SRT2-ROC08 Manual And Instructions
SRT2-ROC08 datasheetPDF datasheet
SRT2-ROC08 SETUP MANUAL

OMRON SRT2-ROC08 Product information and technical parameters:
Brand: OMRON
Name: Relay-mounted Remote I/O Terminals
Model: SRT2-ROC08
classification: Relay output.
I/O points: 8 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available.

Name: Expansion Units.
Specifications: inputs ;
8 inputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON SRT2-ROC08.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-ROC08
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON SRT2-ROC08. Name: Slice I/O Units; Analog I/O Units.
Specifications: Analog outputs (current).
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON SRT2-ROC08.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 outputs NPN.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs, PPNP (- common), 32 inputs SRT2-ROC08.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easiily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring SRT2-ROC08.
User boards attach easily to the DRT2-@D32BV(-1) using screws.