LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
SRT2-ROC16 | OMRON Relay-mounted Remote I/O Terminals SRT2-ROC16
OMRON SRT2-ROC16 Manual And Instructions
SRT2-ROC16 datasheetPDF datasheet
SRT2-ROC16 SETUP MANUAL

OMRON SRT2-ROC16 Product information and technical parameters:
Brand: OMRON
Name: Relay-mounted Remote I/O Terminals
Model: SRT2-ROC16
classification: Relay output.
I/O points: 16 points.
Rated voltage: 24 VDC.
Relay coil rating: 24 VDC.
Applicable relay: G6D-1A.
Ultra-miniature 8-point and 16-point,
Relay-mounted Terminals Ultra-compact.
(8-point models: 101 x 51 x 51 mm (W x H x D);
16-point models: 156 x 51 x 51 mm (W x H x D)),
Power MOS FET Relay and Relay models.
DIN track mounting and screw mounting are available.

Name: Screw Terminal Block with SSR Outputs.
Specifications: Outputs;
8 outputs; SSR.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRT2-ROC16.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site SRT2-ROC16
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs, PNP (- common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications OMRON SRT2-ROC16. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance OMRON SRT2-ROC16.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices.
(Models with 16 outputs and models with 16 mixed I/O)Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min.
(between each input terminal and the G terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the G terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansiion unit per one I/O terminal unit SRT2-ROC16. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software SRT2-ROC16.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.


...More relevant models >>>>
Last one: OMRON SRT2-ID04MX
next one: OMRON SRT2-ROC08