Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 75A.
Weight: 5.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm
MY2-02-E AC220/240
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Unit classification: CJ1 Special I/O Units.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface:Pulse-train line-driver,
output with Pulse Counter Function;
Number of control axes : 4 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.31A; 24V, --.
Standards: UC1, CE.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed.
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
MY2-02-E AC220/240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MY2-02-E AC220/240&select=5