LK Automation Limited LK Automation Limited
Brand: OMRON
Go Back >> Product Catalogues
S8VK-R Series | OMRON Redundancy Unit S8VK-R Series
OMRON S8VK-R Series Manual And Instructions
S8VK-R Series datasheetPDF datasheet
S8VK-R Series datasheetPDF datasheet

OMRON S8VK-R Series Product information and technical parameters:
Brand: OMRON
Name: Redundancy Unit
Model: S8VK-R Series
Contribute to build high reliable systems.
Compact and Cost-effective solution.
for Back-up applications.
Easy setup for system reliability.
requirement.
Redundancy operating LED for the status confirmation.
A signal output for failure detection of power supplies.
By adjusting the power supply voltage to light up Balance LED,
the lifetime of power supplies will be more than twice.
Wide range input.
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20).
Wide operation temperature range: -40 to 70 °C.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1 Lloyd''s standards *2.
EMS: EN61000-6-2.
EMI: EN61000-6-3.
Six years warranty *3.

Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON S8VK-R Series.
Detect three-phase AC current for under and/or overcur,
rent using current converter S8VK-R Series
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) OMRON S8VK-R Series.
LED operation indicator.
UL/CSA approval (SDV-F@). Power rating: 35 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 15 V VDC.
Output current: 2.4 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation OMRON S8VK-R Series.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Mounting method: Embedded with screw threads.
Pin shape: Solder cup pin.
Applicable wire diameter: AWG22 to 28.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements annd ensure a,
94V-0 fire retardant rating S8VK-R Series.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on S8VK-R Series.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.


...More relevant models >>>>
Last one: OMRON S8VK-T96024
next one: OMRON S8VK-R10